Schluter DHERS/BW Installation Guide Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
WOOD — Floors, Interior 7
Floors, Interior - Existing Vinyl Floors
Areas of Application
over any even and structurally sound
substrate with existing vinyl flooring
interior dry or wet areas
Limitations
minimum 2" x 2" (50 mm x 50 mm) tile
cushioned vinyl unacceptable
perimeter bonded vinyl flooring unacceptable
multiple layers of vinyl unacceptable
Requirements
for wood substrates, subfloor/underlayment
configuration according to detail DH-W16-T,
DH-W19-T, DH-W24-T, or DH-W-S
Substrate Preparation
ensure that the structure beneath the vinyl is
sound and adequate
ensure that vinyl is well adhered
remove any wax and clean vinyl
for wood substrates, nail off floor with ring
shank flooring nails every 4" (102 mm) o.c.
– fasteners must pass through entire
thickness of assembly with minimal
penetration into joists
any leveling of the subfloor must be done
prior to installing DITRA-HEAT.
Movement Joints
DITRA-HEAT does not eliminate the need for
movement joints, including perimeter joints,
within the tiled surface. Movement joints must
be installed in accordance with industry
standards and norms; see page 11 of this
Handbook, TCNA EJ171, and TTMAC 301 MJ.
Setting and Grouting Materials
Fast-setting latex portland cement (p.c.)
mortar – ANSI A118.4 or A118.15
unmodified thin-set mortar – ANSI A118.1
grout – ANSI A118.3, A118.6, A118.7, A118.8
Setting and Grouting Specifications
tile – ANSI A108.5
grout – ANSI A108.6, A108.9, A108.10
Other Considerations
DITRA-HEAT is adhered to the vinyl flooring
using a fast-setting latex-portland cement
mortar suitable for bonding to vinyl. As an
alternative, a suitable cement-based
embossing leveler or an appropriate latex-
modified thin-set mortar can be used to skim
coat the vinyl to provide a bonding surface.
When skim coat is cured, DITRA-HEAT is
adhered to the skim coat using an unmodified
thin-set mortar. See page 21 for discussion
on latex-modified thin-set mortars
sandwiched between two impervious layers.
seaming DITRA-HEAT, including floor/wall
connections, with KERDI-BAND may be
appropriate in cases where a break in the
water line of an ice maker or dishwasher can
damage pre-existing moisture-sensitive
substrates and underlayments. KERDI-BAND
floor/wall connections are just as easily
concealed with wood base as with tile.
KERDI-BAND floor/wall connections in
dishwasher alcoves are parged with thin-set
mortar; see page 10.
vapor barrier on crawl space floors according
to regional building codes.
certain moisture-sensitive stones, e.g., green
marble, or resin-backed tiles may require
special setting materials. Consult stone
supplier and Schluter
®
-Systems for more
information.
Floors, Interior - Structural Plank Subfloor
Areas of Application
over structural plank subfloors
interior dry or wet areas
Limitations
minimum 2" x 2" (50 mm x 50 mm) tile
Requirements
maximum spacing of joists is 24" (610 mm) o.c.
double layer wood floor consisting of:
minimum structural plank subfloor
thickness – 3/4" (19 mm)
minimum underlayment thickness –
15/32", 1/2" nom. (13 mm)
Substrate Preparation
verify that subfloor planks are properly
fastened to framing members.
underlayment – minimum 15/32", 1/2" nom.
(13 mm)-thick Exposure 1, plugged-face
plywood or OSB with 1/8" (3 mm) gap
between sheets; see page 14 for
underlayment installation guidelines.
any leveling of the subfloor must be done
prior to installing DITRA-HEAT.
Movement Joints
DITRA-HEAT does not eliminate the need for
movement joints, including perimeter joints,
within the tiled surface. Movement joints must
be installed in accordance with industry
standards and norms; see page 11 of this
Handbook, TCNA EJ171, and TTMAC 301 MJ.
Setting and Grouting Materials
latex portland cement (p.c.) mortar –
ANSI A118.11
unmodified thin-set mortar – ANSI A118.1
grout – ANSI A118.3, A118.6, A118.7, A118.8
Setting and Grouting Specifications
tile – ANSI A108.5
grout – ANSI A108.6, A108.9, A108.10
Other Considerations
vapor barrier on crawl space floors according
to regional building codes.
where a waterproof floor is required, all
DITRA-HEAT seams and floor/wall transitions
must be sealed with KERDI-BAND using
unmodified thin-set mortar; see page 10.
certain moisture-sensitive stones, e.g., green
marble, or resin-backed tiles may require
special setting materials. Consult stone
supplier and Schluter
®
-Systems for more
information.
DH-SP-TS-15
DH-V-T-15
Tile or wood base
Ceramic or stone tile
RONDEC
DILEX-EKE
Unmodified thin-set mortar
KERDI-BAND
DITRA-HEAT
uncoupling membrane
and heating cables
Fast-setting
latex p.c. mortar
Existing vinyl
Plywood or OSB
Joists, I-joists, or
trusses
Ceramic or stone tile
Unmodified thin-set mortar
DITRA-HEAT
uncoupling membrane
and heating cables
Latex p.c. mortar
Plywood or OSB
underlayment
Structural plank
subfloor
Joists
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 27 28

Comments to this Manuals

No comments